LUMIX 3 PLUS

About the product
This new generation of laser equipment has the following main features:
• 3 types of laser emission: Continuous, Pulsed and Superpulsed
• 3 different wavelengths (650, 808, 910nm)
• individual activation of the different laser sources
• synchronisation of activation of the laser sources
• optical overlapping of the laser sources spots
• high peak power (from 100W)
• high average powers (from 5W )
• high pulse repetition (up to 100,000 per second)
• the ability to interact therapeutically with different tissue depths.
Having high peak powers available allows transferring the average power generated by the
laser sources deeply inside human tissues.
An important feature of the new lasers LUMIX® 3 with C.P.S.® technology is a high peak
power as well as a high average power.

LUMIX® 3 Plus
A versatile laser:
• 3 pulsed-superpulsed diodes
and 1 diode CW of 3,2W;
• 600W: maximum peak power;
• 100W: minimum peak power;
• high average power equal to 5W;
• excellent tissue penetration for
fast treatments.

Tissue penetration
Among the factors allowing a laser light to penetrate the human tissues, wavelength and
peak power are essential.
It is important for the laser wavelength to fall within the so-called “therapeutic window”
namely 600 to 1400 nanometers.
The lasers LUMIX® 3 emit in a wavelength of 650, 808, 904÷910 nanometers.
At the same wavelength the peak power is indispensable to reach deeply in the tissue.
Using a laser with high peak powers is therefore absolutely necessary to reach the deep layers. The minimum peak power of the lasers LUMIX® 3 ranges WITH a minimum of 100 Watts .

C.P.S.® Laser System Fisioline®
Using high pulsation frequencies (over 40 KHz: super pulse) permits to exploit a physical
phenomenon new for laser devices, that is the photomechanical effect i.e. the transformation,
at a molecular level, of light EM energy into mechanical energy.
This can increase the effects on the conduction structures, that is on the muscular
tissues (decontracturing), and on nervous tissues (antalgia), and also on fibrous tissues
(improvement of the elasticity) with the same lambda and power.
The use of the 3.2W CW continuous laser diode, on the other hand, allows a
photomodulating effect (analgesic, anti-oedemagenous, stimulating, in relation to the
density of energy administered) to be achieved on the cutaneous receptors.
A wide frequency adjustment range (both manually and automatically) and the
association of the different emission modalities, an exclusive feature of the
C.P.S.® system, make the laser devices LUMIX® 3 extremely versatile.

Large spots
The size of the output spot has a considerable importance. This is the surface where the
laser radiation is evenly distributed (power density in W/cm2). The larger the spot
size, with the same power density, the higher the laser penetration in the
tissues, thanks to the scattering sum.
The spot of LUMIX® 3 laser devices has a diameter ranging from about 2 cm to more than
10 cm. Independently from the position of the optical unit on the patient, the output angle
should always less than 15° to avoid reflection (beyond 30° any laser or normal light
would be almost entirely reflected).
Besides adopting the contact irradiation technique, these characteristics allow the laser
devices LUMIX® 3 to carry laser and thermal energy deep in the tissues.
Price
45,950 RM
Contact with supplier
BACK TO TOP